M-ION EXPLOSIVE VAPOR AND TRACE DETECTOR

General Specifications

  • Threshold sensitivity in vapor mode (for TNT at 20 °C and 80% humidity), g/cm3 : Better than 10-14 (1ppt)
  • Threshold sensitivity in particle mode (for TNT), pg ; 100
  • Technology : Field Asymmetric Ion Mobility Spectrometry (FAIMS)
  • Radiation source : NO
  • Calibration : Not required
  • Type of ionization : corona discharge
  • Explosives detected : TNT, RDX, PETN, ANFO, EGDN, Nitroglycerine (NG), Dynamite, DNT, Black Powder, Ammonia and Urea nitrates, HMTD, Tetryl and mixtures thereof
  • Alarm type :Audio and visual, with substance identification
  • Options : Searching radiometer
  • Warm up time, minutes : not more than 1
  • Analysis and results time, seconds : 2 - 8
  • False alarm rate : Less than 1%
  • Time of continuous work in standalone mode, hours not less than 2
  • Display ; 109mm (4.3in) color TFT display with touch screen
  • Available accessories : Sampling tube, remote preconcentrator, shoulder strap for carrying M-ION
  • Operating temperature, °C (°F) : from minus 0(32) to +55(131)
  • Operation humidity at 25°C (77°F) : 95% non-condensing
  • Operation altitude, m (ft) : up to 5000 (16 404)
  • Dimensions (L х W х H), mm (in) : 400х160х110 (15,75x6,30x4,33)
  • Weight, kg (lb) 2,4 kg (5.29 lb)

M-ION can detect and identify a wide variety of explosives including pure explosives and composite explosives under different humidity and pressure conditions in vapour and trace (particles mode).

The list of explosives includes TNT, RDX, C4, Semtex, PETN, ANFO, EGDN, Nitroglycerine (NG), Dynamite, DNT, Black Powder , Ammonia and Urea nitrates, HMTD, Tetryl and mixtures thereof.

The cost of ownership of M-ION is very low, as special consumables are not required. Regular aluminum foil napkins are used for surface wiping.

M-ION runs on the Field Asymmetric Ion Mobility Spectrometry principle. M-ION contains no radiation sources. Corona discharge functions as the source of ionization.

M-ION features user authorization function with the internal memory which allows to save more than 100K results of analysis.

M-ION does not require a special calibration.

M-ION is equipped with a special electrostatic valve filtering ions by their polarity, which significantly reduces false alarm rate from non-explosive materials.

M-ION warms up in less than 1 minute.

M-ION is easy to use and doesn’t require any special training.

Presence of an explosive in the sample is visualized on the LCD display of the device or any Wi-Fi device usable as a remote control.