Specification

  • Test Range: 0 - 5mm (0.2in) up to 0 - 10000 mm (400 in.) at steel velocity. Variable in 1mm & 10mm steps.
  • Velocity: 1000 to 9,999m/s continuously variable.
  • Probe Zero: 0 to 999.999 μs, continuously variable.
  • Delay: Calibrated delay from 0-10000mm in 0.05 mm steps at steel velocity (0-400in. in 0.002 in. steps).
  • Gain: 0 to 110dB. Adjustable in 0.5, 1, 2, 6, 10, 14 and 20dB steps.
  • Test Modes: Pulse echo and transmit/receive.

  • Using the latest developments in amplifier and pulser technology to deliver higher levels of near surface resolution and penetrating power the Railscan 125 Ultrasonic Flaw Detector has been developed and designed specifically for Rail Testing within the Rail Infrastructure NDT market.