sage-banner

Events

AirChek XR5000 5 to 5000 ml/min

AirChek XR5000 5 to 5000 ml/min

Specifications

  • Flow Range1000 to 5000 ml/min (5 to 500 ml/min requires optional low flow kit)
  • Compensation Range5000 ml/min at 10 inches water back pressure 4000 ml/min at 20 inches water back pressure 2000 ml/min at 50 inches water back pressure
  • Flow Compensation SystemPatented isothermal closed loop flow sensor (U.S. Patent No. 5,892,160)
  • Tubing Requires 1/4-inch ID tubing
  • Battery Charge Level IndicatorIcon displays on LCD at full, mid, low charge, imminent low battery fault, and low battery fault.
  • Temperature RangeOperating: 32 to 104 F (0 to 40 C) Charging: 32 to 113 F (0 to 45 C) Storage: -4 to 95 F (-20 to 35 C)
  • Timer Display Range 1 to 9999 minutes (6.8 days). If run time exceeds 6.8 days, timer display rolls over.
  • Flow FaultIf pump is unable to compensate for > 15 seconds due to excessive back pressure, the pump stops and holds run time display. Auto-restart is attempted every 15 seconds up to 5 times.
  • Low Battery Fault15 sec to sleep
  • Auto-off 5 min of inactivity
  • Battery PackHigh-power Li-Ion (4 cell), rechargeable, 7.4 V, 4.4 Ah, 32.6 Wh capacity or Standard Li-Ion (2 cell), rechargeable, 7.4 V, 2.2 Ah, 16.3 Wh capacity
  • Battery Recharge Time Standard Li-Ion (2 cell): approximately 4 hrs High-power Li-Ion (4 cell): approximately 8 hrs
  • Size High-power Li-Ion model: 5.5 x 3 x 2.3 in (14 x 7.6 x 5.8 cm) Standard Li-Ion model: 4.3 x 3 x 2.3 in (10.9 x 7.6 x 5.8 cm)
  • WeightHigh-power Li-Ion model: 21 oz (0.6 kg) Standard Li-Ion model: 16 oz (0.45 kg)
  • CaseAnti-static plastic
  • RFI/EMI ShieldingCE marked for RFI/EMI protection
  • Approvals for use in hazardous locations. Models that are UL Listed for intrinsic safety contain the logo on the label. These models must be used with battery pack Cat. No. P85004 or P85002 to maintain the UL intrinsic safety listing. RoHS compliant
Download Brochures

Discover the perfect combination of features and power in this compact, lightweight pump that gets the job done. The AirChekĀ® XR5000 personal air sampling pump with Li-Ion battery provides powerful flows for particulate sampling, low flows for gas and vapor sampling, and the long run-times for low-concentration sampling. The AirChek XR5000 air sampling pump is UL Listed for intrinsic safety.

  • Flow Range1000 to 5000 ml/min (5 to 500 ml/min requires optional low flow kit)
  • Compensation Range5000 ml/min at 10 inches water back pressure 4000 ml/min at 20 inches water back pressure 2000 ml/min at 50 inches water back pressure
  • Flow Compensation SystemPatented isothermal closed loop flow sensor (U.S. Patent No. 5,892,160)
  • Tubing Requires 1/4-inch ID tubing
  • Battery Charge Level IndicatorIcon displays on LCD at full, mid, low charge, imminent low battery fault, and low battery fault.
  • Temperature RangeOperating: 32 to 104 F (0 to 40 C) Charging: 32 to 113 F (0 to 45 C) Storage: -4 to 95 F (-20 to 35 C)
  • Timer Display Range 1 to 9999 minutes (6.8 days). If run time exceeds 6.8 days, timer display rolls over.
  • Flow FaultIf pump is unable to compensate for > 15 seconds due to excessive back pressure, the pump stops and holds run time display. Auto-restart is attempted every 15 seconds up to 5 times.
  • Low Battery Fault15 sec to sleep
  • Auto-off 5 min of inactivity
  • Battery PackHigh-power Li-Ion (4 cell), rechargeable, 7.4 V, 4.4 Ah, 32.6 Wh capacity or Standard Li-Ion (2 cell), rechargeable, 7.4 V, 2.2 Ah, 16.3 Wh capacity
  • Battery Recharge Time Standard Li-Ion (2 cell): approximately 4 hrs High-power Li-Ion (4 cell): approximately 8 hrs
  • Size High-power Li-Ion model: 5.5 x 3 x 2.3 in (14 x 7.6 x 5.8 cm) Standard Li-Ion model: 4.3 x 3 x 2.3 in (10.9 x 7.6 x 5.8 cm)
  • WeightHigh-power Li-Ion model: 21 oz (0.6 kg) Standard Li-Ion model: 16 oz (0.45 kg)
  • CaseAnti-static plastic
  • RFI/EMI ShieldingCE marked for RFI/EMI protection
  • Approvals for use in hazardous locations. Models that are UL Listed for intrinsic safety contain the logo on the label. These models must be used with battery pack Cat. No. P85004 or P85002 to maintain the UL intrinsic safety listing. RoHS compliant