sage-banner

Events

FLIR Griffin™ G400-Series

FLIR Griffin™ G400-Series

Specifications

  • Technology GC/MS; fully integrated low thermal mass gas chromatograph (LTM-GC) and MS/MS-capable ion trap mass analyzer
  • Mass Range / Scan Rate 35-425 m/z; up to 10,000 m/z per second @ 20 points per m/z
  • Ionization Type Internal electron ionization (EI)
  • Detector Conversion dynode electron multiplier
  • LTM-GC Column Standard VB-5MS (15M x .25mm x .25um); others available; programmable 40 to 300 °C
  • Calibrant Onboard FC-43 (Perfluorotributylamine)
  • Carrier Gas Connection for external gas source (choice of He or H2); gas available from many vendors; H2 generator available
  • Sample Phase Solid and liquid
  • Threats Detects and identifies explosives, narcotics, CWAs, TICs, environmental pollutants, and other chemicals
  • Display & Alerts Full automation by connection with computer
  • Communication Ethernet connection TCP/IP; remote operation and diagnostics
  • Data Storage Data automatically stored on supplied laptop (500 gb)
  • Storage Temp -13 to 131°F (-25 to 55°C)
  • Weight 80.5 lbs (36.5 kg)
  • Operating Temp / Humidity 41 to 104 °F (5 to 40 °C); <85% relative humidity
Download Brochures

The FLIR Griffin G400-series GC/MS (Gas Chromatograph / Mass Spectrometer) products provide best-in-class chemical identification and are built to operate in reconnaissance vehicles, mobile labs, deployable lab containers, and other portable platforms.

  • Technology GC/MS; fully integrated low thermal mass gas chromatograph (LTM-GC) and MS/MS-capable ion trap mass analyzer
  • Mass Range / Scan Rate 35-425 m/z; up to 10,000 m/z per second @ 20 points per m/z
  • Ionization Type Internal electron ionization (EI)
  • Detector Conversion dynode electron multiplier
  • LTM-GC Column Standard VB-5MS (15M x .25mm x .25um); others available; programmable 40 to 300 °C
  • Calibrant Onboard FC-43 (Perfluorotributylamine)
  • Carrier Gas Connection for external gas source (choice of He or H2); gas available from many vendors; H2 generator available
  • Sample Phase Solid and liquid
  • Threats Detects and identifies explosives, narcotics, CWAs, TICs, environmental pollutants, and other chemicals
  • Display & Alerts Full automation by connection with computer
  • Communication Ethernet connection TCP/IP; remote operation and diagnostics
  • Data Storage Data automatically stored on supplied laptop (500 gb)
  • Storage Temp -13 to 131°F (-25 to 55°C)
  • Weight 80.5 lbs (36.5 kg)
  • Operating Temp / Humidity 41 to 104 °F (5 to 40 °C); <85% relative humidity